Well electrical diagnostic
📍 Winchester
Found no power at the control box and high amp draw on the well circuit. Documented drop-pipe and breaker work needed before the pump can be pulled.
Real completed jobs from our crew across San Diego, Riverside, and San Bernardino counties. These July and August 2026 jobs include pump replacements, diagnostics, pressure-tank work, and control-panel repairs.
📍 Winchester
Found no power at the control box and high amp draw on the well circuit. Documented drop-pipe and breaker work needed before the pump can be pulled.
📍 Ramona
Diagnosed a pump that slowly climbs in amps. Confirmed a pull-and-evaluate is the next step and listed the equipment already in the well.
📍 Jamul
Diagnosed high-amp overload trips on a 1.5 HP well that feeds storage. The submersible cable needs a ground and the pump should be pulled.
📍 Jamul
Ran timed bucket tests on a 1.5 HP well set at 481 feet. Recalibrated the pump saver so the well has enough recovery time between cycles.
📍 Ramona
Evaluated a noisy 5 HP three-phase vertical booster. It still built pressure; documented tank and drive options for a quieter long-term fix.
📍 Santa Ysabel
Bailed gravel and drill mud and brushed the 4-1/2 inch liner. Replaced the above-ground check valve and pumped the well back into service.
📍 Temecula
On-site inspection of a shallow wellhead, casing, and electrical connections so the owner has a clear picture of the setup.
📍 Jamul
Found high amp draw and a near-short on the submersible cable. Recommended a pull-and-replace with new wire and a pump saver.
📍 Murrieta
Reviewed a two-tank setup after larger tanks were swapped in for a working unit. Checked how the new tanks were affecting system cycle.
📍 Thermal
Replaced a 30/50 pressure switch on a hydropneumatic tank and checked the tank float. Also evaluated a worn booster that was overheating.
📍 Ramona
Replaced blown disconnect fuses and measured startup amps on an irrigation well. Recommended a pull-and-replace on the aging pump set.
📍 Ramona
Installed a new 240-volt contactor so the well could start cleanly again.
📍 Warner Springs
Cleaned debris out of the pressure switch and cycled the pump. The system returned to normal cut-in and cut-out.
📍 Pauma Valley
Pulled and replaced a 2 HP pump and motor under warranty after a dead-head blew a hole in the drop pipe. Set a new 7 GPM pump at about 704 feet.
📍 El Cajon
Replaced a failed 1-1/4 inch check valve on the house booster so pressure would hold again.
📍 Ramona
Swapped in a new 2 HP booster. The pump cycled normally and the system was left running.
📍 Poway
Timed bucket tests on a 2 HP well feeding storage. Recorded about 8 GPM at start, dropping as the well drew down.
📍 Palomar Mountain
Replaced the mechanical seal on the pump so it would hold pressure again.
📍 Aguanga
Diagnosed a 1 HP well that tripped on undercurrent and would not recover volume. Calibrated the pump saver and confirmed the pump needs to be pulled.
📍 Ramona
Replaced a locked-up 2 HP booster. The new pump came up to pressure with no extra plumbing needed.
📍 Murrieta
Timed recovery on a well that shut off after short run times. Recorded amp draw and recommended a new 40/60 switch and control-box service.